Coresight already reported an error if a different clock was used, but this also applies to SPE so add the same error there.
Signed-off-by: James Clark james.clark@linaro.org --- tools/perf/arch/arm/util/cs-etm.c | 2 +- tools/perf/arch/arm64/util/arm-spe.c | 6 ++++++ 2 files changed, 7 insertions(+), 1 deletion(-)
diff --git a/tools/perf/arch/arm/util/cs-etm.c b/tools/perf/arch/arm/util/cs-etm.c index 809da6f1a892..5a64c17cf254 100644 --- a/tools/perf/arch/arm/util/cs-etm.c +++ b/tools/perf/arch/arm/util/cs-etm.c @@ -365,7 +365,7 @@ static int cs_etm_recording_options(struct auxtrace_record *itr, return ret;
if (opts->use_clockid) { - pr_err("Cannot use clockid (-k option) with %s\n", + pr_err("Cannot use clockid (-k option) with %s, can only correlate samples with the default clock.\n", CORESIGHT_ETM_PMU_NAME); return -EINVAL; } diff --git a/tools/perf/arch/arm64/util/arm-spe.c b/tools/perf/arch/arm64/util/arm-spe.c index 53899c7de846..834419f04617 100644 --- a/tools/perf/arch/arm64/util/arm-spe.c +++ b/tools/perf/arch/arm64/util/arm-spe.c @@ -416,6 +416,12 @@ static int arm_spe_recording_options(struct auxtrace_record *itr, evsel->pmu->name); return -EINVAL; } + + if (opts->use_clockid) { + pr_err("Cannot use clockid (-k option) with %s, can only correlate samples with the default clock.\n", + evsel->pmu->name); + return -EINVAL; + } } }