The programming clock is enabled by AMBA bus driver before a dynamic probe. As a result, a CoreSight driver may redundantly enable the same clock.
To avoid this, add a check for device type and skip enabling the programming clock for AMBA devices. The returned NULL pointer will be tolerated by the drivers.
Fixes: 73d779a03a76 ("coresight: etm4x: Change etm4_platform_driver driver for MMIO devices") Signed-off-by: Leo Yan leo.yan@arm.com --- include/linux/coresight.h | 11 +++++++---- 1 file changed, 7 insertions(+), 4 deletions(-)
diff --git a/include/linux/coresight.h b/include/linux/coresight.h index b888f6ed59b2..26eb4a61b992 100644 --- a/include/linux/coresight.h +++ b/include/linux/coresight.h @@ -476,15 +476,18 @@ static inline bool is_coresight_device(void __iomem *base) * Returns: * * clk - Clock is found and enabled + * NULL - Clock is not needed as it is managed by the AMBA bus driver * ERROR - Clock is found but failed to enable */ static inline struct clk *coresight_get_enable_apb_pclk(struct device *dev) { - struct clk *pclk; + struct clk *pclk = NULL;
- pclk = devm_clk_get_enabled(dev, "apb_pclk"); - if (IS_ERR(pclk)) - pclk = devm_clk_get_enabled(dev, "apb"); + if (!dev_is_amba(dev)) { + pclk = devm_clk_get_enabled(dev, "apb_pclk"); + if (IS_ERR(pclk)) + pclk = devm_clk_get_enabled(dev, "apb"); + }
return pclk; }