Hi Zeng Tao,
On Wed, Jan 3, 2018 at 8:30 PM, Zeng Tao prime.zeng@hisilicon.com wrote:
when the current process is doing a rpc call from optee, and if there is a signal pending on the process, it will enter dead loop if the tee-supplicant is working correctly, fix the problem by breaking out the loop when the rpc job is finished.
Signed-off-by: Zeng Tao prime.zeng@hisilicon.com
drivers/tee/optee/supp.c | 7 +++++++ 1 file changed, 7 insertions(+)
diff --git a/drivers/tee/optee/supp.c b/drivers/tee/optee/supp.c index b4ea067..170dedb 100644 --- a/drivers/tee/optee/supp.c +++ b/drivers/tee/optee/supp.c @@ -107,6 +107,13 @@ u32 optee_supp_thrd_req(struct tee_context *ctx, u32 func, size_t num_params, mutex_unlock(&supp->ctx_mutex); if (interruptable) break;
/*
* if there is signal pending, and the supplicant has finished
* the rpc job, we need to break out the loop
*/
if (try_wait_for_completion(&supp->data_from_supp))
break; } ret = supp->ret;
-- 2.7.4
Since this patch was posted there has been changes (during the merge window) to this part of the code. Please rebase, test and post again.
Thanks, Jens