commit 459b1e8c8fe97fcba0bd1b623471713dce2c5eaf upstream.
The analog input subdevice supports Comedi asynchronous commands that use Comedi's 16-bit sample format. However, the call to `comedi_buf_write_samples()` is passing the address of a 32-bit integer variable. On bigendian machines, this will copy 2 bytes from the wrong end of the 32-bit value. Fix it by changing the type of the variable holding the sample value to `unsigned short`.
Fixes: ad9eb43c93d8 ("staging: comedi: das800: use comedi_buf_write_samples()") Cc: stable@vger.kernel.org # 3.19+ Signed-off-by: Ian Abbott abbotti@mev.co.uk Link: https://lore.kernel.org/r/20210223143055.257402-6-abbotti@mev.co.uk Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/staging/comedi/drivers/das800.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/staging/comedi/drivers/das800.c +++ b/drivers/staging/comedi/drivers/das800.c @@ -427,7 +427,7 @@ static irqreturn_t das800_interrupt(int struct comedi_cmd *cmd; unsigned long irq_flags; unsigned int status; - unsigned int val; + unsigned short val; bool fifo_empty; bool fifo_overflow; int i;