4.14-stable review patch. If anyone has any objections, please let me know.
------------------
From: Viresh Kumar viresh.kumar@linaro.org
[ Upstream commit af0e09d0c6762e486b0eb5cc4737396964c34fad ]
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device.
Add such missing properties.
Signed-off-by: Viresh Kumar viresh.kumar@linaro.org Signed-off-by: Masahiro Yamada yamada.masahiro@socionext.com Signed-off-by: Sasha Levin alexander.levin@microsoft.com Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi | 2 ++ 1 file changed, 2 insertions(+)
--- a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi +++ b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi @@ -55,6 +55,7 @@ clocks = <&sys_clk 32>; enable-method = "psci"; operating-points-v2 = <&cluster0_opp>; + #cooling-cells = <2>; };
cpu2: cpu@100 { @@ -73,6 +74,7 @@ clocks = <&sys_clk 33>; enable-method = "psci"; operating-points-v2 = <&cluster1_opp>; + #cooling-cells = <2>; }; };