On Fri, May 12, 2023 at 11:07:10AM +0200, Francesco Dolcini wrote:
Hello all, I recently did have a regression on v6.4rc1, and it seems that the same exact issue is now happening also on v6.1.28.
I was not able yet to bisect it (yet), but what is happening is that libusbgx[1] that we use to configure a USB NCM gadget interface[2][3] just hang completely at boot.
This is happening with multiple ARM32 and ARM64 i.MX SOC (i.MX6, i.MX7, i.MX8MM).
The logs is something like that
[* �F] A start job is running for Load def…t schema g1.schema (6s / no limit) M[K[** �F] A start job is running for Load def…t schema g1.schema (7s / no limit) M[K[*** �F] A start job is running for Load def…t schema g1.schema (8s / no limit) M[K[ *** �F] A start job is running for Load def…t schema g1.schema (8s / no limit)
I will try to bisect this and provide more useful feedback ASAP, I decided to not wait for it and just send this email in case someone has some insight on what is going on.
Thanks for the report. I'm adding it to regzbot:
#regzbot ^introduced: 0db213ea8eed55 #regzbot titile: libusbgx hang completely at boot (stuck at loading g1.schema)