On Mon, 05 May 2025 21:20:06 +0200 Sean Nyekjaer sean@geanix.com wrote:
Add the correct scale to get temperature in mili degree Celcius. Add sign component to temperature scan element.
Signed-off-by: Sean Nyekjaer sean@geanix.com
Applied.
Thanks,
Changes in v4:
- Blindly Copy/Pasted Andy's comment. Use the correct MILLIDEGREE_PER_DEGREE
- Link to v3: https://lore.kernel.org/r/20250505-fxls-v3-0-8c541bf0205c@geanix.com
Changes in v3:
- Dropping define infavor of inline scale value
- Added using constants from units.h
- Tweaked commit msg to make it more assertive
- Link to v2: https://lore.kernel.org/r/20250502-fxls-v2-0-e1af65f1aa6c@geanix.com
Changes in v2:
- Correct offset is applied before scaling component
- Added sign component to temperature scan element
- Link to v1: https://lore.kernel.org/r/20250501-fxls-v1-1-f54061a07099@geanix.com
Sean Nyekjaer (2): iio: accel: fxls8962af: Fix temperature calculation iio: accel: fxls8962af: Fix temperature scan element sign
drivers/iio/accel/fxls8962af-core.c | 15 +++++++++++++-- 1 file changed, 13 insertions(+), 2 deletions(-)
base-commit: 609bc31eca06c7408e6860d8b46311ebe45c1fef change-id: 20250501-fxls-307ef3d6d065
Best regards,