From: Hans Verkuil hverkuil-cisco@xs4all.nl
commit 13cbaa4c2b7bf9f8285e1164d005dbf08244ecd5 upstream.
When the reply for a non-blocking transmit arrives, the sequence field for that reply was never filled in, so userspace would have no way of associating the reply to the original transmit.
Copy the sequence field to ensure that this is now possible.
Signed-off-by: Hans Verkuil hverkuil-cisco@xs4all.nl Fixes: 0dbacebede1e ([media] cec: move the CEC framework out of staging and to media) Cc: stable@vger.kernel.org Signed-off-by: Mauro Carvalho Chehab mchehab+huawei@kernel.org Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/media/cec/cec-adap.c | 1 + 1 file changed, 1 insertion(+)
--- a/drivers/media/cec/cec-adap.c +++ b/drivers/media/cec/cec-adap.c @@ -1146,6 +1146,7 @@ void cec_received_msg_ts(struct cec_adap if (abort) dst->rx_status |= CEC_RX_STATUS_FEATURE_ABORT; msg->flags = dst->flags; + msg->sequence = dst->sequence; /* Remove it from the wait_queue */ list_del_init(&data->list);