6.6-stable review patch. If anyone has any objections, please let me know.
------------------
From: Alexander Stein alexander.stein@ew.tq-group.com
commit fdada0db0b2ae2addef4ccafe50937874dbeeebe upstream.
This reverts commit 75fd6485cccef269ac9eb3b71cf56753341195ef. This patch was applied twice by accident, causing probe failures. Revert the accident.
Signed-off-by: Alexander Stein alexander.stein@ew.tq-group.com Fixes: 75fd6485ccce ("usb: phy: generic: Get the vbus supply") Cc: stable stable@kernel.org Reviewed-by: Sean Anderson sean.anderson@seco.com Link: https://lore.kernel.org/r/20240314092628.1869414-1-alexander.stein@ew.tq-gro... Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/usb/phy/phy-generic.c | 7 ------- 1 file changed, 7 deletions(-)
--- a/drivers/usb/phy/phy-generic.c +++ b/drivers/usb/phy/phy-generic.c @@ -268,13 +268,6 @@ int usb_phy_gen_create_phy(struct device return dev_err_probe(dev, PTR_ERR(nop->vbus_draw), "could not get vbus regulator\n");
- nop->vbus_draw = devm_regulator_get_exclusive(dev, "vbus"); - if (PTR_ERR(nop->vbus_draw) == -ENODEV) - nop->vbus_draw = NULL; - if (IS_ERR(nop->vbus_draw)) - return dev_err_probe(dev, PTR_ERR(nop->vbus_draw), - "could not get vbus regulator\n"); - nop->dev = dev; nop->phy.dev = nop->dev; nop->phy.label = "nop-xceiv";