Hi,
Am 22.08.2025 um 08:51 schrieb H. Nikolaus Schaller hns@goldelico.com:
What do you mean with "catched earlier"? What is your proposal?
Well, as proposed by Jerry earlier, it appears as if it can also be handled in bq27xxx_battery_hdq_read() by detecting the register BQ27XXX_REG_FLAGS and the read value 0xff and return -ENODEV.
I tried this but there are more locations where BQ27XXX_REG_FLAGS are read and where the reading code is not prepared to receive an -ENODEV. This will for example emit
[ 293.389831] w1_slave_driver 01-000000000000: error reading flags
each time the battery is removed. And in some race cases (a read of the full /sys properties is already in progress), there may be more than one such message. That is not nice to replace one console message with another...
So I am not sure if it is a good idea to make the lowest layer ("catched earlier") read function detect -ENODEV based on the register number. It can not know what the next layer wants to do with the result.