On 9/23/25 5:59 AM, Guangshuo Li wrote:
devm_kcalloc() may fail. ndtest_probe() allocates three DMA address arrays (dcr_dma, label_dma, dimm_dma) and later unconditionally uses them in ndtest_nvdimm_init(), which can lead to a NULL pointer dereference under low-memory conditions.
Check all three allocations and return -ENOMEM if any allocation fails. Do not emit an extra error message since the allocator already warns on allocation failure.
Fixes: 9399ab61ad82 ("ndtest: Add dimms to the two buses") Cc: stable@vger.kernel.org Signed-off-by: Guangshuo Li lgs201920130244@gmail.com
Changes in v2:
- Drop pr_err() on allocation failure; only NULL-check and return -ENOMEM.
- No other changes.
tools/testing/nvdimm/test/ndtest.c | 3 +++ 1 file changed, 3 insertions(+)
diff --git a/tools/testing/nvdimm/test/ndtest.c b/tools/testing/nvdimm/test/ndtest.c index 68a064ce598c..abdbe0c1cb63 100644 --- a/tools/testing/nvdimm/test/ndtest.c +++ b/tools/testing/nvdimm/test/ndtest.c @@ -855,6 +855,9 @@ static int ndtest_probe(struct platform_device *pdev) p->dimm_dma = devm_kcalloc(&p->pdev.dev, NUM_DCR, sizeof(dma_addr_t), GFP_KERNEL);
- if (!p->dcr_dma || !p->label_dma || !p->dimm_dma)
return -ENOMEM;
Why not just check as it allocates instead of doing it all at the end? If an allocation failed, no need to attempt to allocate more (which probably leads to more failures).
DJ
- rc = ndtest_nvdimm_init(p); if (rc) goto err;