From: Stefan Agner stefan@agner.ch
[ Upstream commit 9e454e37dc7c0ee9e108d70b983e7a71332aedff ]
According to the datasheet (Rev. 1.9) the RTL8211F requires at least 72ms "for internal circuits settling time" before accessing the PHY egisters. On similar boards with the same PHY this fixes an issue where Ethernet link would not come up when using ip link set down/up.
Fixes: 2cd2310fca4c ("arm64: dts: meson-g12b-ugoos-am6: add initial device-tree") Reviewed-by: Martin Blumenstingl martin.blumenstingl@googlemail.com Signed-off-by: Stefan Agner stefan@agner.ch Signed-off-by: Kevin Hilman khilman@baylibre.com Link: https://lore.kernel.org/r/46298e66572784c44f873f1b71cc4ab3d8fc5aa6.160736352... Signed-off-by: Sasha Levin sashal@kernel.org --- arch/arm64/boot/dts/amlogic/meson-g12b-w400.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm64/boot/dts/amlogic/meson-g12b-w400.dtsi b/arch/arm64/boot/dts/amlogic/meson-g12b-w400.dtsi index 2802ddbb83ac7..feb0885047400 100644 --- a/arch/arm64/boot/dts/amlogic/meson-g12b-w400.dtsi +++ b/arch/arm64/boot/dts/amlogic/meson-g12b-w400.dtsi @@ -264,7 +264,7 @@ max-speed = <1000>;
reset-assert-us = <10000>; - reset-deassert-us = <30000>; + reset-deassert-us = <80000>; reset-gpios = <&gpio GPIOZ_15 (GPIO_ACTIVE_LOW | GPIO_OPEN_DRAIN)>;
interrupt-parent = <&gpio_intc>;