On 02/07/2024 16:52, Krzysztof Kozlowski wrote:
Linux kernel uses thermal zone node name during registering thermal zones and has a hard-coded limit of 20 characters, including terminating NUL byte. The bindings expect node names to finish with '-thermal' which is eight bytes long, thus we have only 11 characters for the reset of the node name (thus 10 for the pattern after leading fixed character).
Reported-by: Rob Herring robh@kernel.org Closes: https://lore.kernel.org/all/CAL_JsqKogbT_4DPd1n94xqeHaU_J8ve5K09WOyVsRX3jxxU... Fixes: 1202a442a31f ("dt-bindings: thermal: Add yaml bindings for thermal zones") Cc: stable@vger.kernel.org Signed-off-by: Krzysztof Kozlowski krzysztof.kozlowski@linaro.org
Applied, thanks