From: Andrzej Pietrasiewicz andrzej.p@samsung.com
[ Upstream commit c07c1a0f68d0f2f7ca9aff924e2772526027b019 ]
The TOP "aclk400_mscl" clock should be kept enabled all the time to allow proper access to power management control for MSC power domain and devices that are a part of it. This change is required for the scaler to work properly after domain power on/off sequence.
Fixes: 318fa46cc60d ("clk/samsung: exynos542x: mark some clocks as critical") Signed-off-by: Andrzej Pietrasiewicz andrzej.p@samsung.com Signed-off-by: Marek Szyprowski m.szyprowski@samsung.com Signed-off-by: Sylwester Nawrocki s.nawrocki@samsung.com Signed-off-by: Sasha Levin sashal@kernel.org --- drivers/clk/samsung/clk-exynos5420.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/samsung/clk-exynos5420.c b/drivers/clk/samsung/clk-exynos5420.c index cdc092a1d9ef..07fb667e258f 100644 --- a/drivers/clk/samsung/clk-exynos5420.c +++ b/drivers/clk/samsung/clk-exynos5420.c @@ -987,7 +987,7 @@ static const struct samsung_gate_clock exynos5x_gate_clks[] __initconst = { GATE(0, "aclk400_isp", "mout_user_aclk400_isp", GATE_BUS_TOP, 16, 0, 0), GATE(0, "aclk400_mscl", "mout_user_aclk400_mscl", - GATE_BUS_TOP, 17, 0, 0), + GATE_BUS_TOP, 17, CLK_IS_CRITICAL, 0), GATE(0, "aclk200_disp1", "mout_user_aclk200_disp1", GATE_BUS_TOP, 18, CLK_IS_CRITICAL, 0), GATE(CLK_SCLK_MPHY_IXTAL24, "sclk_mphy_ixtal24", "mphy_refclk_ixtal24",