Hello,
Dmitry Korotin wrote:
Added missing EHB (Execution Hazard Barrier) in mtc0 -> mfc0 sequence. Without this execution hazard barrier it's possible for the value read back from the KScratch register to be the value from before the mtc0.
Reproduciable on P5600 & P6600.
Mips documentation Volume III (rev 6.03) table 8.1.
Signed-off-by: Dmitry Korotin dkorotin@wavecomp.com
Applied to mips-fixes.
Thanks, Paul
[ This message was auto-generated; if you believe anything is incorrect then please email paul.burton@mips.com to report it. ]