On 08/11/24 02:08, A. Sverdlin wrote:
From: Alexander Sverdlin alexander.sverdlin@siemens.com
Currently "timeout-sec" Device Tree property is being silently ignored: even though watchdog_init_timeout() is being used, the driver always passes "heartbeat" == DEFAULT_HEARTBEAT == 60 as argument.
Fix this by setting struct watchdog_device::timeout to DEFAULT_HEARTBEAT and passing real module parameter value to watchdog_init_timeout() (which may now be 0 if not specified).
Cc: stable@vger.kernel.org Fixes: 2d63908bdbfb ("watchdog: Add K3 RTI watchdog support") Signed-off-by: Alexander Sverdlin alexander.sverdlin@siemens.com
drivers/watchdog/rti_wdt.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/drivers/watchdog/rti_wdt.c b/drivers/watchdog/rti_wdt.c index f410b6e39fb6f..58c9445c0f885 100644 --- a/drivers/watchdog/rti_wdt.c +++ b/drivers/watchdog/rti_wdt.c @@ -61,7 +61,7 @@ #define MAX_HW_ERROR 250 -static int heartbeat = DEFAULT_HEARTBEAT; +static int heartbeat; /*
- struct to hold data for each WDT device
@@ -252,6 +252,7 @@ static int rti_wdt_probe(struct platform_device *pdev) wdd->min_timeout = 1; wdd->max_hw_heartbeat_ms = (WDT_PRELOAD_MAX << WDT_PRELOAD_SHIFT) / wdt->freq * 1000;
- wdd->timeout = DEFAULT_HEARTBEAT; wdd->parent = dev;
watchdog_set_drvdata(wdd, wdt);
LGTM. Thanks for the fix!
Reviewed-by: Vignesh Raghavendra vigneshr@ti.com