From: Manish Chopra manishc@marvell.com
[ Upstream commit dc5a3d79c345871439ffe72550b604fcde9770e1 ]
PF driver doesn't enable tx-switching for all cos queues/clients, which causes packets drop from PF to VF. Fix this by enabling tx-switching on all cos queues/clients.
Signed-off-by: Manish Chopra manishc@marvell.com Signed-off-by: David S. Miller davem@davemloft.net Signed-off-by: Sasha Levin sashal@kernel.org --- .../net/ethernet/broadcom/bnx2x/bnx2x_sriov.c | 16 +++++++++++----- 1 file changed, 11 insertions(+), 5 deletions(-)
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c index 0edbb0a768472..5097a44686b39 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c @@ -2397,15 +2397,21 @@ static int bnx2x_set_pf_tx_switching(struct bnx2x *bp, bool enable) /* send the ramrod on all the queues of the PF */ for_each_eth_queue(bp, i) { struct bnx2x_fastpath *fp = &bp->fp[i]; + int tx_idx;
/* Set the appropriate Queue object */ q_params.q_obj = &bnx2x_sp_obj(bp, fp).q_obj;
- /* Update the Queue state */ - rc = bnx2x_queue_state_change(bp, &q_params); - if (rc) { - BNX2X_ERR("Failed to configure Tx switching\n"); - return rc; + for (tx_idx = FIRST_TX_COS_INDEX; + tx_idx < fp->max_cos; tx_idx++) { + q_params.params.update.cid_index = tx_idx; + + /* Update the Queue state */ + rc = bnx2x_queue_state_change(bp, &q_params); + if (rc) { + BNX2X_ERR("Failed to configure Tx switching\n"); + return rc; + } } }