From: Hans de Goede hdegoede@redhat.com
[ Upstream commit 3d0818f5eba80fbe4c0addbfe6ddb2d19dc82cd4 ]
The Lex 3I380D industrial PC has 4 ethernet controllers on board which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks as CLK_CRITICAL and they will not get turned off.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Reported-and-tested-by: Semyon Verchenko semverchenko@factor-ts.ru Signed-off-by: Hans de Goede hdegoede@redhat.com Acked-by: Andy Shevchenko andy.shevchenko@gmail.com Signed-off-by: Andy Shevchenko andriy.shevchenko@linux.intel.com Signed-off-by: Sasha Levin sashal@kernel.org --- drivers/platform/x86/pmc_atom.c | 9 +++++++++ 1 file changed, 9 insertions(+)
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index 50f2a125cd2c..e3e1f83a2dd7 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -428,12 +428,21 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc) */ static const struct dmi_system_id critclk_systems[] = { { + /* pmc_plt_clk0 is used for an external HSIC USB HUB */ .ident = "MPL CEC1x", .matches = { DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"), DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"), }, }, + { + /* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */ + .ident = "Lex 3I380D", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"), + DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), + }, + }, { /*sentinel*/ } };