On Sat, Aug 29, 2020 at 03:42:50PM +0200, Bjørn Mork wrote:
The USB composition, defining the set of exported functions, is dynamic in newer Quectel modems. Default functions can be disabled and alternative functions can be enabled instead. The alternatives includes class functions using interface pairs, which should be handled by the respective class drivers.
Active interfaces are numbered consecutively, so static blacklisting based on interface numbers will fail when the composition changes. An example of such an error, where the option driver has bound to the CDC ECM data interface, preventing cdc_ether from handling this function:
T: Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#= 2 Spd=480 MxCh= 0 D: Ver= 2.00 Cls=ef(misc ) Sub=02 Prot=01 MxPS=64 #Cfgs= 1 P: Vendor=2c7c ProdID=0125 Rev= 3.18 S: Manufacturer=Quectel S: Product=EC25-AF C:* #Ifs= 6 Cfg#= 1 Atr=a0 MxPwr=500mA A: FirstIf#= 4 IfCount= 2 Cls=02(comm.) Sub=06 Prot=00 I:* If#= 0 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=option E: Ad=81(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 1 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=83(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=02(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 2 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=85(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=84(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=03(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 3 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=87(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=86(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=04(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 4 Alt= 0 #EPs= 1 Cls=02(comm.) Sub=06 Prot=00 Driver=(none) E: Ad=89(I) Atr=03(Int.) MxPS= 16 Ivl=32ms I:* If#= 5 Alt= 0 #EPs= 0 Cls=0a(data ) Sub=00 Prot=00 Driver=option I: If#= 5 Alt= 1 #EPs= 2 Cls=0a(data ) Sub=00 Prot=00 Driver=option E: Ad=88(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=05(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
Another device with the same id gets correct drivers, since the interface of the network function happens to be blacklisted by option:
T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 3 Spd=480 MxCh= 0 D: Ver= 2.00 Cls=ef(misc ) Sub=02 Prot=01 MxPS=64 #Cfgs= 1 P: Vendor=2c7c ProdID=0125 Rev= 3.18 S: Manufacturer=Android S: Product=Android C:* #Ifs= 5 Cfg#= 1 Atr=a0 MxPwr=500mA I:* If#= 0 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=option E: Ad=81(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 1 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=83(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=02(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 2 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=85(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=84(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=03(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 3 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option E: Ad=87(I) Atr=03(Int.) MxPS= 10 Ivl=32ms E: Ad=86(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=04(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms I:* If#= 4 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=qmi_wwan E: Ad=89(I) Atr=03(Int.) MxPS= 8 Ivl=32ms E: Ad=88(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms E: Ad=05(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
Change rules for EC21, EC25, BG96 and EG95 to match vendor specific serial functions only, to prevent binding to class functions. Require 2 endpoints on ff/ff/ff functions, avoiding the 3 endpoint QMI/RMNET network functions.
Cc: AceLan Kao acelan.kao@canonical.com Cc: Sebastian Sjoholm ssjoholm@mac.com Cc: Dan Williams dcbw@redhat.com Cc: stable@vger.kernel.org Signed-off-by: Bjørn Mork bjorn@mork.no
Thanks, Bjørn. Now applied.