From: Lars-Peter Clausen lars@metafoo.de
commit 6661146427cbbce6d1fe3dbb11ff1c487f55799a upstream.
IIO trigger handlers must call iio_trigger_notify_done() when done. This must be done even when an error occurred. Otherwise the trigger will be seen as busy indefinitely and the trigger handler will never be called again.
The ad7768-1 driver neglects to call iio_trigger_notify_done() when there is an error reading the converter data. Fix this by making sure that iio_trigger_notify_done() is included in the error exit path.
Fixes: a5f8c7da3dbe ("iio: adc: Add AD7768-1 ADC basic support") Signed-off-by: Lars-Peter Clausen lars@metafoo.de Link: https://lore.kernel.org/r/20211101144055.13858-2-lars@metafoo.de Cc: Stable@vger.kernel.org Signed-off-by: Jonathan Cameron Jonathan.Cameron@huawei.com Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/iio/adc/ad7768-1.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/iio/adc/ad7768-1.c +++ b/drivers/iio/adc/ad7768-1.c @@ -470,8 +470,8 @@ static irqreturn_t ad7768_trigger_handle iio_push_to_buffers_with_timestamp(indio_dev, &st->data.scan, iio_get_time_ns(indio_dev));
- iio_trigger_notify_done(indio_dev->trig); err_unlock: + iio_trigger_notify_done(indio_dev->trig); mutex_unlock(&st->lock);
return IRQ_HANDLED;