From: Hans de Goede hdegoede@redhat.com
commit ad3d9c779b1f09f3f3a6fefd07af407c7bc7c9a7 upstream.
The bq25892 model relies on external charger-type detection and once that is done the bq25890_charger code will update the input current and if pumpexpress is used also the input voltage.
In this case, when the initial power_supply_changed() call is made from the interrupt handler, the input settings are 5V/0.5A which on many devices is not enough power to charge (while the device is on).
On many devices the fuel-gauge relies in its external_power_changed callback to timely signal userspace about charging <-> discharging status changes. Add a power_supply_changed() call after updating the input current or voltage. This allows the fuel-gauge driver to timely recheck if the battery is charging after the new input settings have been applied and then it can immediately notify userspace about this.
Fixes: 48f45b094dbb ("power: supply: bq25890: Support higher charging voltages through Pump Express+ protocol") Fixes: eab25b4f93aa ("power: supply: bq25890: On the bq25892 set the IINLIM based on external charger detection") Signed-off-by: Hans de Goede hdegoede@redhat.com Signed-off-by: Sebastian Reichel sebastian.reichel@collabora.com Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/power/supply/bq25890_charger.c | 3 +++ 1 file changed, 3 insertions(+)
--- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -775,6 +775,7 @@ static void bq25890_charger_external_pow }
bq25890_field_write(bq, F_IINLIM, input_current_limit); + power_supply_changed(psy); }
static int bq25890_get_chip_state(struct bq25890_device *bq, @@ -1106,6 +1107,8 @@ static void bq25890_pump_express_work(st dev_info(bq->dev, "Hi-voltage charging requested, input voltage is %d mV\n", voltage);
+ power_supply_changed(bq->charger); + return; error_print: bq25890_field_write(bq, F_PUMPX_EN, 0);