The current signal handling tests for SME do not account for the fact that unlike SVE all SME vector lengths are optional so we can't guarantee that we will encounter the minimum possible VL, they will hang enumerating VLs on such systems. Abort enumeration when we find the lowest VL in the newly added ssve_za_regs test.
Fixes: bc69da5ff087 ("kselftest/arm64: Verify simultaneous SSVE and ZA context generation") Signed-off-by: Mark Brown broonie@kernel.org --- tools/testing/selftests/arm64/signal/testcases/ssve_za_regs.c | 4 ++++ 1 file changed, 4 insertions(+)
diff --git a/tools/testing/selftests/arm64/signal/testcases/ssve_za_regs.c b/tools/testing/selftests/arm64/signal/testcases/ssve_za_regs.c index 954a21f6121a..1f62621794d5 100644 --- a/tools/testing/selftests/arm64/signal/testcases/ssve_za_regs.c +++ b/tools/testing/selftests/arm64/signal/testcases/ssve_za_regs.c @@ -34,6 +34,10 @@ static bool sme_get_vls(struct tdescr *td)
vl &= PR_SME_VL_LEN_MASK;
+ /* Did we find the lowest supported VL? */ + if (vq < sve_vq_from_vl(vl)) + break; + /* Skip missing VLs */ vq = sve_vq_from_vl(vl);