On Mon, 24 Jan 2022 at 13:19, liupeng (DM) liupeng256@huawei.com wrote: [...]
When KFENCE pool size can be adjusted by boot parameters(assumption), automatically test and train KFENCE may be useful. So far, exporting kfence.sample_interval is not necessary.
I'm not opposed to the patch (I've also run into this issue, but not too frequently) - feel free to just send it with EXPORT_SYMBOL_GPL.